Water Cooled Chiller

Scroll Compressor

P-SHW-S SERIES

 

Conveyor belt - nds series

Planer water cooled water chillers are designed to be used for process cooling and HVAC applications. Capacity range of standard models are between 9.6 kW and 975 kW. As standard scroll, reciprocating and screw compressors are used. Compressors are energy efficient and long-lasting. Plate heat exchangers and shell and tube used as water cooled condensers. Microprocessor controllers are used on water cooled chillers for optimum capacity control. Pump and water tanks are delivered as standard for scroll and reciprocating copressors and are optional for screw compressors. The pump and water tank data given is for reference. Please consult us for different conditions. Low temperature glycol water chillers (0℃/-40℃) can be manufactured on demand. Higher efficiency standard classes and lower sound levels can be achieved by special design of the chillers upon request. Evaporative cooling system can be applied as an option. The products, designed by special computer softwares, have competitive advantages based on initial investment and operating costs. All of the materials, used on the chillers are in high quality and long-term durability. Products, designed as robust, have long industrial life. The chillers have GOST/EAC certification and CE marking.

Automatic hopper loader - ral300i - rhong
Automatic hopper loader - ral300i - rhong
Automatic hopper loader - ral300i - rhong

Technical Specifications

  • 16 kW – 58 kW capacity range
  • Hermetic scroll compressor
  • Microprocessor control unit
  • Environmental friendly refrigerant R 407 C
  • Plate heat exchangers and shell and tube used as water cooled condenser and evaporators
  • Electricity and power panel with CE 2006/96/EC standards
  • High pressure safety device for condensers
  • Centrifugal water pump
  • Inoxidable water tank
  • Double cooling circuit for the devices with double compressors
  • Protective equipments essential for gas line and water line
  • Compressor equal aging

Options

  • Inverter compressor 
  • Remote monitoring module
  • Automation of double temperatures of cold water
  • Free cooling automation 
Conveyor belt - nds series

 

Model

P 041 SHW-S P 071 SHW-S P 081 SHW-S P 101 SHW-S P 121 SHW-S P 151 SHW-S
Refrigerant R 407 C
Performance values for referance condition 1 
T water outlet – 15 ℃; T water inlet – 20 ℃; T water inlet – 30 ℃
Cooling capacity kW 16.0 26.8 34.0 41.6 49.4 58.2
kcal/h 13.767 23.059 29.254 35.793 42.505 50.076
Total compressor power kW 2.4 4.1 5.1 6.5 7.3 11.2
Performance values for referance condition 2
T water outlet – 7 ℃; T water inlet – 12 ℃; T water inlet – 30 ℃
Cooling capacity kW 11.6 20.1 24.4 30.1 35.8 43.4
kcal/h 9.981 17.924 20.994 25.899 30.803 37.342
Total compressor power kW 2.3 3.9 5.0 5.9 7.1 11.0
Number of compressors pcs. 1 1 1 1 1 1
Pump power ( for 3 bars) kW 0.75 1.5 1.5 2.2 2.2 2.2
Tank volume Lt. 80 80 100 100 100 120
Required evaporator flow m³/h 3 5 6 7 8 10
Required evaporator flow m³/h 7 10 15 30 40 50

 

Model

P 072 SHW-S

P 082 SHW-S

P 102 SHW-S

P 122 SHW-S

P 152 SHW-S

Refrigerant R 407 C
Performance values for referance condition 1 
T water outlet – 15 ℃; T water inlet – 20 ℃; T water inlet – 30 ℃
Cooling capacity kW 53.6 68.0 83.2 98.8 116.4
kcal/h 46.119 58.509 71.587 85.010 100.153
Total compressor power kW 8.2 10.2 13.0 14.6 22.4
Performance values for referance condition 2
T water outlet – 7 ℃; T water inlet – 12 ℃; T water inlet – 30 ℃
Cooling capacity kW 40.2 48.8 60.2 71.6 86.8
kcal/h 34.589 41.989 51.797 61.606 74.685
Total compressor power kW 7.8 10.0 11.8 14.2 22.0
Number of compressors pcs. 2 2 2 2 2
Pump power ( for 3 bars) kW 2.2 3 3 4 4
Tank volume Lt. 120 160 180 200 220
Required evaporator flow m³/h 9 12 14 17 20
Required evaporator flow m³/h 20 30 60 80 100

 

DIMENSIONS

Model

P 041 SHW-S

P 071 SHW-S

P 081 SHW-S

P 101 SHW-S

P 121 SHW-S 

P 151 SHW-S

P 072 SHW-S

P 082 SHW-S

P 102 SHW-S

P 122 SHW-S

P 152 SHW-S

 
L mm 950 950 1000 1000 1000 1200 1200 1200 1400 1400 1600
W mm 600 600 650 650 650 650 800 800 900 900 1100
H mm 1235 1235 1335 1335 1335 1335 1335 1335 1600 1600 1600
Water inlet connection 1” 1” 1 ½” 1 ½” 1 ½” 1 ½” 2” 2” 2 ½” 2 ½” 2 ½”
Water outlet connection 1” 1” 1 ½” 1 ½” 1 ½” 1 ½” 2” 2” 2 ½” 2 ½” 2 ½”
Weight kg 200 350 400 410 430 460 500 580 620 640 700

Technical Data

P 041 SHW-S
Model P 041 SHW-S
Refrigerant R 407 C
Performance values for referance condition 1
T water outlet – 15 ℃; T water inlet – 20 ℃; T water inlet – 30 ℃
Cooling capacity kW 16.0
kcal/h 13.767
Total compressor power kW 2.4
Performance values for referance condition 2
T water outlet – 7 ℃; T water inlet – 12 ℃; T water inlet – 30 ℃
Cooling capacity kW 11.6
kcal/h 9.981
Total compressor power kW 2.3
Number of compressors pcs. 1
Pump power ( for 3 bars) kW 0.75
Tank volume Lt. 80
Required evaporator flow m³/h 3
Required evaporator flow m³/h 7
DIMENSIONS    
Model P 041 SHW-S
L mm 950
W mm 600
H mm 1235
Water inlet connection 1”
Water outlet connection 1”
Weight kg 200
P 071 SHW-S
Model P 071 SHW-S
Refrigerant R 407 C
Performance values for referance condition 1
T water outlet – 15 ℃; T water inlet – 20 ℃; T water inlet – 30 ℃
Cooling capacity kW 26.8
kcal/h 23.059
Total compressor power kW 4.1
Performance values for referance condition 2
T water outlet – 7 ℃; T water inlet – 12 ℃; T water inlet – 30 ℃
Cooling capacity kW 20.1
kcal/h 17.924
Total compressor power kW 3.9
Number of compressors pcs. 1
Pump power ( for 3 bars) kW 1.5
Tank volume Lt. 80
Required evaporator flow m³/h 5
Required evaporator flow m³/h 10

 

Model P 071 SHW-S
L mm 950
W mm 600
H mm 1235
Water inlet connection 1”
Water outlet connection 1”
Weight kg 350
P 081 SHW-S
Model P 081 SHW-S
L mm 1000
W mm 650
H mm 1335
Water inlet connection 1 ½”
Water outlet connection 1 ½”
Weight kg 400
P 101 SHW-S
Model P 101 SHW-S
Refrigerant R 407 C
Performance values for referance condition 1
T water outlet – 15 ℃; T water inlet – 20 ℃; T water inlet – 30 ℃
Cooling capacity kW 41.6
kcal/h 35.793
Total compressor power kW 6.5
Performance values for referance condition 2
T water outlet – 7 ℃; T water inlet – 12 ℃; T water inlet – 30 ℃
Cooling capacity kW 30.1
kcal/h 25.899
Total compressor power kW 5.9
Number of compressors pcs. 1
Pump power ( for 3 bars) kW 2.2
Tank volume Lt. 100
Required evaporator flow m³/h 7
Required evaporator flow m³/h 30

 

DIMENSIONS    
Model P 101 SHW-S
L mm 1000
W mm 650
H mm 1335
Water inlet connection 1 ½”
Water outlet connection 1 ½”
Weight kg 410

 

P 121 SHW-S
Model P 121 SHW-S
Refrigerant R 407 C
Performance values for referance condition 1
T water outlet – 15 ℃; T water inlet – 20 ℃; T water inlet – 30 ℃
Cooling capacity kW 49.4
kcal/h 42.505
Total compressor power kW 7.3
Performance values for referance condition 2
T water outlet – 7 ℃; T water inlet – 12 ℃; T water inlet – 30 ℃
Cooling capacity kW 35.8
kcal/h 30.803
Total compressor power kW 7.1
Number of compressors pcs. 1
Pump power ( for 3 bars) kW 2.2
Tank volume Lt. 100
Required evaporator flow m³/h 8
Required evaporator flow m³/h 40

 

DIMENSIONS    
Model P 121 SHW-S 
L mm 1000
W mm 650
H mm 1335
Water inlet connection 1 ½”
Water outlet connection 1 ½”
Weight kg 430
P 151 SHW-S
Model P 151 SHW-S
Refrigerant R 407 C
Performance values for referance condition 1
T water outlet – 15 ℃; T water inlet – 20 ℃; T water inlet – 30 ℃
Cooling capacity kW 58.2
kcal/h 50.076
Total compressor power kW 11.2
Performance values for referance condition 2
T water outlet – 7 ℃; T water inlet – 12 ℃; T water inlet – 30 ℃
Cooling capacity kW 43.4
kcal/h 37.342
Total compressor power kW 11.0
Number of compressors pcs. 1
Pump power ( for 3 bars) kW 2.2
Tank volume Lt. 120
Required evaporator flow m³/h 10
Required evaporator flow m³/h 50

 

 

DIMENSIONS    
Model P 151 SHW-S
L mm 1200
W mm 650
H mm 1335
Water inlet connection 1 ½”
Water outlet connection 1 ½”
Weight kg 460

 

P 072 SHW-S
Model P 072 SHW-S
Refrigerant R 407 C
Performance values for referance condition 1
T water outlet – 15 ℃; T water inlet – 20 ℃; T water inlet – 30 ℃
Cooling capacity kW 53.6
kcal/h 46.119
Total compressor power kW 8.2
Performance values for referance condition 2
T water outlet – 7 ℃; T water inlet – 12 ℃; T water inlet – 30 ℃
Cooling capacity kW 40.2
kcal/h 34.589
Total compressor power kW 7.8
Number of compressors pcs. 2
Pump power ( for 3 bars) kW 2.2
Tank volume Lt. 120
Required evaporator flow m³/h 9
Required evaporator flow m³/h 20

 

DIMENSIONS    
Model P 072 SHW-S
L mm 1200
W mm 800
H mm 1335
Water inlet connection 2”
Water outlet connection 2”
Weight kg 500
P 082 SHW-S
Model P 082 SHW-S
Refrigerant R 407 C
Performance values for referance condition 1
T water outlet – 15 ℃; T water inlet – 20 ℃; T water inlet – 30 ℃
Cooling capacity kW 68.0
kcal/h 58.509
Total compressor power kW 10.2
Performance values for referance condition 2
T water outlet – 7 ℃; T water inlet – 12 ℃; T water inlet – 30 ℃
Cooling capacity kW 48.8
kcal/h 41.989
Total compressor power kW 10.0
Number of compressors pcs. 2
Pump power ( for 3 bars) kW 3
Tank volume Lt. 160
Required evaporator flow m³/h 12
Required evaporator flow m³/h 30

 

DIMENSIONS    
Model P 082 SHW-S
L mm 1200
W mm 800
H mm 1335
Water inlet connection 2”
Water outlet connection 2”
Weight kg 580
P 102 SHW-S
Model P 102 SHW-S
Refrigerant R 407 C
Performance values for referance condition 1
T water outlet – 15 ℃; T water inlet – 20 ℃; T water inlet – 30 ℃
Cooling capacity kW 83.2
kcal/h 71.587
Total compressor power kW 13.0
Performance values for referance condition 2
T water outlet – 7 ℃; T water inlet – 12 ℃; T water inlet – 30 ℃
Cooling capacity kW 60.2
kcal/h 51.797
Total compressor power kW 11.8
Number of compressors pcs. 2
Pump power ( for 3 bars) kW 3
Tank volume Lt. 180
Required evaporator flow m³/h 14
Required evaporator flow m³/h 60

 

DIMENSIONS    
Model P 102 SHW-S
L mm 1400
W mm 900
H mm 1600
Water inlet connection 2 ½”
Water outlet connection 2 ½”
Weight kg 620
P 122 SHW-S
Model P 122 SHW-S
Refrigerant R 407 C
Performance values for referance condition 1
T water outlet – 15 ℃; T water inlet – 20 ℃; T water inlet – 30 ℃
Cooling capacity kW 98.8
kcal/h 85.010
Total compressor power kW 14.6
Performance values for referance condition 2
T water outlet – 7 ℃; T water inlet – 12 ℃; T water inlet – 30 ℃
Cooling capacity kW 71.6
kcal/h 61.606
Total compressor power kW 14.2
Number of compressors pcs. 2
Pump power ( for 3 bars) kW 4
Tank volume Lt. 200
Required evaporator flow m³/h 17
Required evaporator flow m³/h 80

 

 

DIMENSIONS    
Model P 122 SHW-S
L mm 1400
W mm 900
H mm 1600
Water inlet connection 2 ½”
Water outlet connection 2 ½”
Weight kg 640

 

P 152 SHW-S
Model P 152 SHW-S
Refrigerant R 407 C
Performance values for referance condition 1
T water outlet – 15 ℃; T water inlet – 20 ℃; T water inlet – 30 ℃
Cooling capacity kW 116.4
kcal/h 100.153
Total compressor power kW 22.4
Performance values for referance condition 2
T water outlet – 7 ℃; T water inlet – 12 ℃; T water inlet – 30 ℃
Cooling capacity kW 86.8
kcal/h 74.685
Total compressor power kW 22.0
Number of compressors pcs. 2
Pump power ( for 3 bars) kW 4
Tank volume Lt. 220
Required evaporator flow m³/h 20
Required evaporator flow m³/h 100

 

 

DIMENSIONS    
Model P 152 SHW-S
L mm 1600
W mm 1100
H mm 1600
Water inlet connection 2 ½”
Water outlet connection 2 ½”
Weight kg 700

 

Added Value

  • EASY TO USE.
  • LOW MAINTENANCE.
  • SAFE AND RELIABLE.
  • FAST INSTALLATION.

Interested in this product?

Don’t be shy…