Dry Cooler

V Type

PD-V SERIES

 

Dry coolers are designed to be used for meduim and large capacity process cooling and HVAC applications. Capacity range of the standard models is between 122.6 kW and 661,4 kW. The dry coolers are equipped with high efficient heat exchangers, designed with special computer softwares and are made of copper tubes and aluminium fins as standard. Depending on the working enviroment and design, epoxy coated aluminium fins, complete epoxy coated coils and copper fins are avaiable as option. The standard fin spacing is 2.5 mm. The collectors are made from steel and have valves and drain plugs. Refgrigerant curcuits are optimized for water and different rate glycol/water mix. Energy efficient and low noise fans are used. Their motors protection class is IP 54 and insulation class – F.  The dry coolers are designed in industrial aestetics and ergonomics, can be positioned vertical, horizontal and V-type. In winter, the precautions must be taken to prevent heat exchanger from freezing. In order to prevent freezing glycol/water antifreeze must be used. Reccomended antifreeze mix rates could be sent on request. These coolers have competetive advantages based on initial investment and operating costs.

Automatic hopper loader - ral300i - rhong
Automatic hopper loader - ral300i - rhong
Automatic hopper loader - ral300i - rhong

Standard equipment

  • 122 kW – 630 kW capacity range
  • Modular vertical/horizontal coil design
  • Aluminium fin, copper tube fin coil, produced by PLANER
  • High airflow rate axial fans
  • Electricity and power panel with CE 2006/95/EC standards
  • Appropriate to CE97/23/EC pressure equipment directives
  • Centrifugal water pump
  • Inoxidable reserve tank
  • Microprocessor control unit and fan speed controller

Options

  • Epoxi coated aluminium fin for corrosive enviromental resistance
  • Inoxidable body, EC fan
  • Spraying system
  • Self draining system
Conveyor belt - nds series
Conveyor belt - nds series
Conveyor belt - nds series
Conveyor belt - nds series

ENERGY EFFICIENCY

Min. electricity consumption and max.
efficiency is reached by the innovative
solutions.

QUALITY

The devices are manufactured with first
class materials and in a manner of total
quality.

RESPECT TO ENVIROMENT

We focus on using renewable energy
resources and attain compatibility

INNOVATION

Improved by using the most effective
equipment by expert engineers

TECHNICAL SERVICE

Always with you through fast technical
service support.

TEAM

The result is attained by a team working in
complete harmony.

Model

PD-V
80 12 A 5

PD-V
80 13 A 5

PD-V
80 14 A 5

PD-V
80 15 A 5

PD-V
80 22 A 5

PD-V
80 23 A 5

PD-V
80 24 A 5

PD-V
80 25 A 5

Cooling capacity kW 122.6 190.8 247.8 315.8 245.2 381.5 495.6 631.6
Air flow m³/h 44.780 67.420 89.980 112.580 89.560 134.840 179.960 225.160
Number of fans pcs. 2 3 4 5 4 6 8 10
Fan power kW 4.0 6.0 8.0 10.0 8.0 12.0 16.0 20.0
Fan current A 8.0 12.0 16.0 20.0 16.0 24.0 32.0 40.0
Fan sound level ( 10 m ) dBA 50 52 53 54 53 55 56 57
Tube volume L 47.9 72.9 98.0 123.0 95.8 145.8 196.0 246.0

DIMENSIONS

Model

PD-V
80 12 A 5

PD-V
80 13 A 5

PD-V
80 14 A 5

PD-V
80 15 A 5

PD-V
80 22 A 5

PD-V
80 23 A 5

PD-V
80 24 A 5

PD-V
80 25 A 5

L mm 2500 3500 4650 5850 2500 3500 4650 5850
W mm 1860 1860 1860 1860 2320 2320 2320 2320
H mm 2000 2000 2000 2000 2000 2000 2000 2000
Water inlet connection 2” 2½” 2½” 3” 2×2” 2×2 ½” 2×2 ½” 2×3”
Water outlet connection 2” 2½” 2½” 3” 2×2” 2×2 ½” 2×2 ½” 2×3”

Technical Data

PD-V 80 12 A 5
Model PD-V   80 12 A 5
Cooling capacity kW 122.6
Air flow m³/h 44.780
Number of fans pcs. 2
Fan power kW 4.0
Fan current A 8.0
Fan sound level ( 10 m ) dBA 50
Tube volume  L 47.9
DIMENSIONS    
Model PD-V             80 12 A 5
     
L mm 2500
W mm 1860
H mm 2000
Water inlet connection 2”
Water outlet connection 2”

 

PD-V 80 13 A 5
Model PD-V  80 13 A 5
Cooling capacity kW 190.8
Air flow m³/h 67.420
Number of fans pcs. 3
Fan power kW 6.0
Fan current A 12.0
Fan sound level ( 10 m ) dBA 52
Tube volume  L 72.9
DIMENSIONS    
Model PD-V             80 13 A 5
     
L mm 3500
W mm 1860
H mm 2000
Water inlet connection 2½”
Water outlet connection 2½”

 

PD-V 80 14 A 5
Model PD-V   80 14 A 5
Cooling capacity kW 247.8
Air flow m³/h 89.980
Number of fans pcs. 4
Fan power kW 8.0
Fan current A 16.0
Fan sound level ( 10 m ) dBA 53
Tube volume  L 98.0
DIMENSIONS    
Model PD-V             80 14 A 5
     
L mm 4650
W mm 1860
H mm 2000
Water inlet connection 2½”
Water outlet connection 2½”

 

PD-V 80 15 A 5
Model PD-V   80 15 A 5
Cooling capacity kW 315.8
Air flow m³/h 112.580
Number of fans pcs. 5
Fan power kW 10.0
Fan current A 20.0
Fan sound level ( 10 m ) dBA 54
Tube volume  L 123.0
DIMENSIONS    
Model PD-V              80 15 A 5
     
L mm 5850
W mm 1860
H mm 2000
Water inlet connection 3”
Water outlet connection 3”

 

PD-V 80 22 A 5
Model PD-V   80 22 A 5
Cooling capacity kW 245.2
Air flow m³/h 89.560
Number of fans pcs. 4
Fan power kW 8.0
Fan current A 16.0
Fan sound level ( 10 m ) dBA 53
Tube volume L 95.8
DIMENSIONS
Model PD-V            80 22 A 5
L mm 2500
W mm 2320
H mm 2000
Water inlet connection 2×2”
Water outlet connection 2×2”

 

PD-V 80 23 A 5
Model PD-V             80 23 A 5
Cooling capacity kW 381.5
Air flow m³/h 134.840
Number of fans pcs. 6
Fan power kW 12.0
Fan current A 24.0
Fan sound level ( 10 m ) dBA 55
Tube volume  L 145.8
DIMENSIONS    
Model PD-V             80 23 A 5
     
L mm 3500
W mm 2320
H mm 2000
Water inlet connection 2×2 ½”
Water outlet connection 2×2 ½”

 

PD-V 80 24 A 5
Model PD-V             80 24 A 5
Cooling capacity kW 495.6
Air flow m³/h 179.960
Number of fans pcs. 8
Fan power kW 16.0
Fan current A 32.0
Fan sound level ( 10 m ) dBA 56
Tube volume  L 196.0
DIMENSIONS    
Model PD-V             80 24 A 5
     
L mm 4650
W mm 2320
H mm 2000
Water inlet connection 2×2 ½”
Water outlet connection 2×2 ½”

 

PD-V 80 25 A 5
Model PD-V             80 25 A 5
Cooling capacity kW 631.6
Air flow m³/h 225.160
Number of fans pcs. 10
Fan power kW 20.0
Fan current A 40.0
Fan sound level ( 10 m ) dBA 57
Tube volume  L 246.0
DIMENSIONS    
Model PD-V             80 25 A 5
     
L mm 5850
W mm 2320
H mm 2000
Water inlet connection 2×3”
Water outlet connection 2×3”

Added Value

  • EASY TO USE.
  • LOW MAINTENANCE.
  • SAFE AND RELIABLE.
  • FAST INSTALLATION.