DOUBLE TOWER DRYER

D800-840 SERIES

 

Double tower dryer - d800-840 series

The resin dryers of the D series are equipped with TWINTOWER technology and offer process airflow rates ranging from 80 up to 150 m3 /h with dew point up to – 50 °C so as to satisfy any production requirement. The perfect solution for processing hygroscopic polymers in small and medium productions.

Technical Specifications

  • Microprocessor control unit with LCD display and easy programming (type of material selectable from a database and hourly consumption).
  •  Single-hopper or multi-hopper configurations.
  • Control of the regeneration cycle.
  •  Automatic shutdown to prevent the degradation of the granule.
  •  Automatic valve to control cooling water.
  •  Solid-state relays.
  • Filters to protect blowers and molecular sieves.
  •  RS485 ModBus interface.

ACCESSORIES

    • Dew Point instrument.
    • Colour touch screen.
    •  Clogged filter alarm.
    Double tower dryer - d800-840 series
    Double tower dryer - d800-840 series
    Double tower dryer - d800-840 series

    TECHNICAL DATA

    D800

    D801

    D802

    Airflow rate m³/h 80 120 150
    Process temperature MT 70-150 70-150 70-150
    HT 70-190 70-190 70-190
    Dew point -50 -50 -50
    Static pressure mbar 160 170 150
    Process-blower power kW 0.75 1.1 1.5
    Process-heating power MT kW 3.5 3.5 3.5
    HT kW 3.5 5 5
    Regeneration-heating power kW 1.5 1.5 2
    Total power MT kW 6 9.8 10.3
    HT kW 6 11.3 11.8
    Noise level dB(A) <80 <80 <80
    Voltage/Frequency V/Hz 400/50-60 400/50-60 400/50-60
    Dimensions WxDxH mm 523x1027x1392 523x1027x1392 523x1027x1392
    Weight kg 110 120 135

    No. of installable hoppers

    H50

    H75

    H100

    H150

    H200

    H300

    H400

    D800 2 2 1 1
    D801 4 3 2 2 1
    D802 4 4 3 3 2 1 1

    Technical Data

    D800
    TECHNICAL DATA D800
    Airflow rate m³/h 80
    Process temperature MT 70-150
    HT 70-190
    Dew point -50
    Static pressure mbar 160
    Process-blower power kW 0.75
    Process-heating power MT kW 3.5
    HT kW 3.5
    Regeneration-heating power kW 1.5
    Total power MT kW 6
    HT kW 6
    Noise level dB(A) <80
    Voltage/Frequency V/Hz 400/50-60
    Dimensions WxDxH mm 523x1027x1392
    Weight kg 110
    No. of installable hoppers                H50 H75 H100 H150 H200 H300 H400
    D800 2 2 1 1      
    D801
    TECHNICAL DATA D801
    Airflow rate m³/h 120
    Process temperature MT 70-150
    HT 70-190
    Dew point -50
    Static pressure mbar 170
    Process-blower power kW 1.1
    Process-heating power MT kW 3.5
    HT kW 5
    Regeneration-heating power kW 1.5
    Total power MT kW 9.8
    HT kW 11.3
    Noise level dB(A) <80
    Voltage/Frequency V/Hz 400/50-60
    Dimensions WxDxH mm 523x1027x1392
    Weight kg 120

     

    No. of installable hoppers                H50 H75 H100 H150 H200 H300 H400
    D801 4 3 2 2 1    
    D802
    TECHNICAL DATA D802
    Airflow rate m³/h 150
    Process temperature MT 70-150
    HT 70-190
    Dew point -50
    Static pressure mbar 150
    Process-blower power kW 1.5
    Process-heating power MT kW 3.5
    HT kW 5
    Regeneration-heating power kW 2
    Total power MT kW 10.3
    HT kW 11.8
    Noise level dB(A) <80
    Voltage/Frequency V/Hz 400/50-60
    Dimensions WxDxH mm 523x1027x1392
    Weight kg 135

     

    No. of installable hoppers                H50 H75 H100 H150 H200 H300 H400
    D802 4 4 3 3 2 1 1

    Added Value

    •  STABLE PROCESS Control of the process temperature with PID.
    • EASY TO CONTROL The interface, equipped with a keypad and multi-language digital display, offers a constant monitoring of the machine and shows the main parameters such as temperature and dew point.
    •  AIRFLOW MANAGEMENT (AFM) The microprocessor, according to material and throughput, optimizes the operating parameters (airflow rate and temperature) resulting in energy saving. It also prevents the degradation of the polymer.

    Interested in this product?