ALL IN ONE DEHUMIDIFIER AND DRYER
RDC series
The RDC series all-in one dehumidifiers combine dry air dehumidifiers and hot air dehumidifiers to fully meet the drying needs of hygroscopic and non-hygroscopic materials. The capacity of the drying hoppers can be from 28 to 458 liters. An automatic charging device is also attached to the dehumidifier.
Technical Specifications
- P.I.D. controller for precise maintenance of the set temperature
- Hopper made of stainless steel
- Display monitoring the set and actual temperature in real time
- Protective mechanisms against motor overload and overheating of the material
- Detachable air filter that can be easily cleaned
- Universal wheels, making the dryer easy to operate on various machines
- Double condenser providing lower return air temperature
- Special chain design, eliminating problems with belt drive due to high temperatures
- A real-time dew point monitoring device can be added as an option
TECHNICAL DATA |
RDC-
|
RDC-
|
RDC-
|
RDC-
|
RDC-118L/
|
RDC-
|
RDC-
|
RDC-
|
RDC-
|
RDC-
|
RDC-
|
RDC-
|
|
Drying system | |||||||||||||
Process heater power | kW | 3 | 3 | 4 | 4 | 6 | 6 | 6 | 6 | 7.2 | 7.2 | 12 | 12 |
Process blower power | kW | 0.37 | 0.37 | 0.37 | 0.37 | 0.75 | 0.75 | 1.5 | 1.5 | 1.5 | 1.5 | 2 | 2 |
Drying hopper capacity | L | 28 | 38 | 38 | 88 | 118 | 168 | 168 | 228 | 228 | 308 | 308 | 458 |
Dehumidifying system | |||||||||||||
Regeneration heater power | kW | 3 | 3 | 3 | 3 | 3.5 | 3.5 | 3.5 | 3.5 | 4 | 4 | 5.4 | 5.4 |
Regeneration blower power | kW | 0.25 | 0.25 | 0.25 | 0.25 | 0.37 | 0.37 | 0.37 | 0.37 | 0.37 | 0.37 | 0.37 | 0.37 |
Dry air capacity | m³/hr | 30 | 30 | 50 | 50 | 80 | 80 | 120 | 120 | 150 | 150 | 200 | 200 |
Conveying system | |||||||||||||
Conveying blower power | kW | 0.75 | 0.75 | 0.75 | 0.75 | 0.75 | 0.75 | 0.75 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 |
Diameter of conveying hose | inch | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 |
Hopper suction capacity | L | 3 | 3 | 3 | 6 | 6 | 6 | 6 | 12 | 12 | 12 | 12 | 12 |
External dimensions | |||||||||||||
H | mm | 1500 | 1600 | 1600 | 1700 | 1850 | 1850 | 1850 | 2000 | 2100 | 2100 | 2100 | 2300 |
W | mm | 860 | 860 | 860 | 860 | 860 | 860 | 860 | 860 | 1000 | 1000 | 1000 | 1000 |
L | mm | 1100 | 1100 | 1100 | 1100 | 1250 | 1250 | 1250 | 1250 | 1350 | 1350 | 1350 | 1350 |
Weight | kg | 180 | 200 | 240 | 260 | 280 | 290 | 300 | 360 | 500 | 520 | 550 | 580 |
Technical Data
RDC - 28L/30H
TECHNICAL DATA | RDC- 28L/30H | |
Drying system | ||
Process heater power | kW | 3 |
Process blower power | kW | 0.37 |
Drying hopper capacity | L | 28 |
Dehumidifying system | ||
Regeneration heater power | kW | 3 |
Regeneration blower power | kW | 0.25 |
Dry air capacity | m³/hr | 30 |
Conveying system | ||
Conveying blower power | kW | 0.75 |
Diameter of conveying hose | inch | 1.5 |
Hopper suction capacity | L | 3 |
External dimensions | ||
H | mm | 1500 |
W | mm | 860 |
L | mm | 1100 |
Weight | kg | 180 |
RDC - 38L/30H
TECHNICAL DATA | RDC – 38L/30H | |
Drying system | ||
Process heater power | kW | 3 |
Process blower power | kW | 0.37 |
Drying hopper capacity | L | 38 |
Dehumidifying system | ||
Regeneration heater power | kW | 3 |
Regeneration blower power | kW | 0.25 |
Dry air capacity | m³/hr | 30 |
Conveying system | ||
Conveying blower power | kW | 0.75 |
Diameter of conveying hose | inch | 1.5 |
Hopper suction capacity | L | 3 |
External dimensions | ||
H | mm | 1600 |
W | mm | 860 |
L | mm | 1100 |
Weight | kg | 200 |
RDC - 38L/50H
TECHNICAL DATA | RDC- 38L/50H | |
Drying system | ||
Process heater power | kW | 4 |
Process blower power | kW | 0.37 |
Drying hopper capacity | L | 38 |
Dehumidifying system | ||
Regeneration heater power | kW | 3 |
Regeneration blower power | kW | 0.25 |
Dry air capacity | m³/hr | 50 |
Conveying system | ||
Conveying blower power | kW | 0.75 |
Diameter of conveying hose | inch | 1.5 |
Hopper suction capacity | L | 3 |
External dimensions | ||
H | mm | 1600 |
W | mm | 860 |
L | mm | 1100 |
Weight | kg | 240 |
RDC - 88L/50H
TECHNICAL DATA | RDC- 88L/50H | |
Drying system | ||
Process heater power | kW | 4 |
Process blower power | kW | 0.37 |
Drying hopper capacity | L | 88 |
Dehumidifying system | ||
Regeneration heater power | kW | 3 |
Regeneration blower power | kW | 0.25 |
Dry air capacity | m³/hr | 50 |
Conveying system | ||
Conveying blower power | kW | 0.75 |
Diameter of conveying hose | inch | 1.5 |
Hopper suction capacity | L | 6 |
External dimensions | ||
H | mm | 1700 |
W | mm | 860 |
L | mm | 1100 |
Weight | kg | 260 |
RDC - 118L/80H
TECHNICAL DATA | RDC- 118L/80H | |
Drying system | ||
Process heater power | kW | 6 |
Process blower power | kW | 0.75 |
Drying hopper capacity | L | 118 |
Dehumidifying system | ||
Regeneration heater power | kW | 3.5 |
Regeneration blower power | kW | 0.37 |
Dry air capacity | m³/hr | 80 |
Conveying system | ||
Conveying blower power | kW | 0.75 |
Diameter of conveying hose | inch | 1.5 |
Hopper suction capacity | L | 6 |
External dimensions | ||
H | mm | 1850 |
W | mm | 860 |
L | mm | 1250 |
Weight | kg | 280 |
RDC - 168L/80H
TECHNICAL DATA | RDC- 168L/80H | |
Drying system | ||
Process heater power | kW | 6 |
Process blower power | kW | 0.75 |
Drying hopper capacity | L | 168 |
Dehumidifying system | ||
Regeneration heater power | kW | 3.5 |
Regeneration blower power | kW | 0.37 |
Dry air capacity | m³/hr | 80 |
Conveying system | ||
Conveying blower power | kW | 0.75 |
Diameter of conveying hose | inch | 1.5 |
Hopper suction capacity | L | 6 |
External dimensions | ||
H | mm | 1850 |
W | mm | 860 |
L | mm | 1250 |
Weight | kg | 290 |
RDC - 168L/120H
TECHNICAL DATA | RDC- 168L/120H | |
Drying system | ||
Process heater power | kW | 6 |
Process blower power | kW | 1.5 |
Drying hopper capacity | L | 168 |
Dehumidifying system | ||
Regeneration heater power | kW | 3.5 |
Regeneration blower power | kW | 0.37 |
Dry air capacity | m³/hr | 120 |
Conveying system | ||
Conveying blower power | kW | 0.75 |
Diameter of conveying hose | inch | 1.5 |
Hopper suction capacity | L | 6 |
External dimensions | ||
H | mm | 1850 |
W | mm | 860 |
L | mm | 1250 |
Weight | kg | 300 |
RDC - 228L/120H
TECHNICAL DATA | RDC- 228L/120H | |
Drying system | ||
Process heater power | kW | 6 |
Process blower power | kW | 1.5 |
Drying hopper capacity | L | 228 |
Dehumidifying system | ||
Regeneration heater power | kW | 3.5 |
Regeneration blower power | kW | 0.37 |
Dry air capacity | m³/hr | 120 |
Conveying system | ||
Conveying blower power | kW | 1.5 |
Diameter of conveying hose | inch | 1.5 |
Hopper suction capacity | L | 12 |
External dimensions | ||
H | mm | 2000 |
W | mm | 860 |
L | mm | 1250 |
Weight | kg | 360 |
RDC - 308L/150H
TECHNICAL DATA | RDC- 308L/150H | |
Drying system | ||
Process heater power | kW | 7.2 |
Process blower power | kW | 1.5 |
Drying hopper capacity | L | 308 |
Dehumidifying system | ||
Regeneration heater power | kW | 4 |
Regeneration blower power | kW | 0.37 |
Dry air capacity | m³/hr | 150 |
Conveying system | ||
Conveying blower power | kW | 1.5 |
Diameter of conveying hose | inch | 1.5 |
Hopper suction capacity | L | 12 |
External dimensions | ||
H | mm | 2100 |
W | mm | 1000 |
L | mm | 1350 |
Weight | kg | 520 |
RDC - 308L/200H
TECHNICAL DATA | RDC- 308L/200H | |
Drying system | ||
Process heater power | kW | 12 |
Process blower power | kW | 2 |
Drying hopper capacity | L | 308 |
Dehumidifying system | ||
Regeneration heater power | kW | 5.4 |
Regeneration blower power | kW | 0.37 |
Dry air capacity | m³/hr | 200 |
Conveying system | ||
Conveying blower power | kW | 1.5 |
Diameter of conveying hose | inch | 1.5 |
Hopper suction capacity | L | 12 |
External dimensions | ||
H | mm | 2100 |
W | mm | 1000 |
L | mm | 1350 |
Weight | kg | 550 |
RDC - 458L/200H
TECHNICAL DATA | RDC- 458L/200H | |
Drying system | ||
Process heater power | kW | 12 |
Process blower power | kW | 2 |
Drying hopper capacity | L | 458 |
Dehumidifying system | ||
Regeneration heater power | kW | 5.4 |
Regeneration blower power | kW | 0.37 |
Dry air capacity | m³/hr | 200 |
Conveying system | ||
Conveying blower power | kW | 1.5 |
Diameter of conveying hose | inch | 1.5 |
Hopper suction capacity | L | 12 |
External dimensions | ||
H | mm | 2300 |
W | mm | 1000 |
L | mm | 1350 |
Weight | kg | 580 |
Added Value
- EASY TO USE.
- LOW MAINTENANCE.
- SAFE AND RELIABLE.
- FAST INSTALLATION.
Interested in this product?
Don’t be shy…