air cooled chiller

Scroll Compressor

HA-S scroll SERIES

 

Conveyor belt - nds series

Planer air cooled chillers are designed to be used for Process Cooling and HVAC applications. Capacity range of standard models are between 16 – 98 kW (at the conditions of water inlet/outlet – 15/20 and air inlet 25 ) .
As standard Danfoss scroll compressors are used. They are energy efficient and long-lasting.
Microprocessor controllers are used on air cooled chillers for optimum capacity control.
The used pumps are Italian made, from a world famous manufacturer – Pedrollo.

Automatic hopper loader - ral300i - rhong
Automatic hopper loader - ral300i - rhong
Automatic hopper loader - ral300i - rhong

Technical Specifications

  • 16 kW – 98 kW capacity range
  • Hermetic scroll compressor
  • Environment friendly refrigerant R 407 C
  • Direct expansion evaporator
  • 50% – 100% capacity control 
  • Electricity and power panel with CE 2006/95/EC standards 
  • High efficiency air cooled condensers, produced by PLANER
  • Axial fan, Centrifugal water pump
  • Inoxidable reserve tank 
  • Double cooling circuit for the devices with double compressors
  • Protective equipment essential for gas line
  • Compressor equal aging

Options

  • Inverter compressor and water pump 
  • Remote monitoring module
  • EC fan

 

Conveyor belt - nds series
Conveyor belt - nds series

ENERGY EFFICIENCY

Min. electricity consumption and max.
efficiency is reached by the innovative
solutions.

QUALITY

The devices are manufactured with first
class materials and in a manner of total
quality.

RESPECT TO ENVIROMENT

We focus on using renewable energy
resources and attain compatibility

INNOVATION

Improved by using the most effective
equipment by expert engineers

TECHNICAL SERVICE

Always with you through fast technical
service support.

TEAM

The result is attained by a team working in
complete harmony.

Model

P-041 HA-S

P-071 HA-S

P-081 HA-S

P-101 HA-S

P-121 HA-S

P-072 HA-S

P-082 HA-S

P-102 HA-S

P-122 HA-S

Refrigerant  R 407 C
Performance Values For Reference Condition 1
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 25 ℃
Cooling capacity kW 16.0 26.8 34.0 41.5 49.3 53.6 68.0 83.0 98.6
kcal/h 13.767 23.059 29.254 35.690 42.419 46.119 58.509 71.380 84.837
Total compressor power kW 2.7 4.6 5.9 6.9 8.2 9.2 11.8 13.8 16.4
Total power Input kW 3.5 6.1 7.4 8.1 9.4 12.2 14.8 16.2 18.8
Performance Values For Reference Condition 2
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 32 ℃
Cooling capacity kW 15.0 24.9 31.5 38.5 45.5 49.8 63.0 77.0 91.0
kcal/h 12.906 21.424 27.103 33.126 39.149 42.849 54.207 66.252 78.298
Total compressor power kW 3.0 5.2 6.6 7.7 9.2 10.3 13.1 15.4 18.3
Total power Input kW 3.8 6.7 8.1 8.9 10.4 13.3 16.2 17.8 20.7
Performance Values For Reference Condition 3
T-water outlet – 7 ℃ / T – water inlet – 12 ℃ / T-ambient – 35 ℃
Cooling capacity kW 10.0 17.1 21.0 25.9 30.4 34.3 42.0 51.8 60.9
kcal/h 8.604 14.748 18.069 22.285 26.183 29.495 36.138 44.570 52.365
Total compressor power kW 3.4 5.7 7.3 8.5 10.2 11.3 14.6 17.0 20.4
Total power Input kW 4.2 7.2 8.8 9.7 11.4 14.3 17.6 19.4 22.8
Energy efficiency ratio (EER) EER 2.4 2.4 2.4 2.7 2.7 2.4 2.4 2.7 2.7
* EER = Cooling capacity (kW) / Total Power Input (Compressor+Fan) (kW)
Number of compressors pcs. 1 1 1 1 1 2 2 2 2
Number of fans/Fan diameter pcs./mm 1xᴓ500 2xᴓ500 2xᴓ500 2xᴓ630 2xᴓ630 3xᴓ500 3xᴓ500 3xᴓ630 3xᴓ630
Fan sound level dBA 48 51 51 53 53 53 54 43 43
Required evaporator water flow m³ / h 3 5 6 7 8 9 12 14 17
Pump power ( For 3 bars ) kW 0.8 1.5 1.5 2.2 2.2 2.2 2.2 3 3
Tank volume Lt. 120 230 310 400 400 275 275 350 350

 

DIMENSIONS

Model P-041 HA-S P-071 HA-S P-081 HA-S P-101 HA-S P-121 HA-S P-072 HA-S P-082 HA-S P-102 HA-S P-122 HA-S
L mm 1350 1620 2020 2020 2420 2420 2420 2850 2850
W mm 750 900 900 1100 1100 1040 1040 1100 1100
H mm 1310 1310 1310 1440 1440 1440 1440 1500 1500
Water inlet connection 1” 1” 1” 1” 1 ½” 1 ½” 2” 2” 2”
Water outlet connection 1” 1” 1” 1” 1 ½” 1 ½” 2” 2” 2”
Weight kg 210 370 420 500 550 675 725 825 875

Technical Data

P-041 HA-S
Model P-041 HA-S
Refrigerant  R 407 C
Performance Values For Reference Condition 1
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 25 ℃
Cooling capacity kW 16.0
kcal/h 13.767
Total compressor power kW 2.7
Total power Input kW 3.5
Performance Values For Reference Condition 2
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 32 ℃
Cooling capacity kW 15.0
kcal/h 12.906
Total compressor power kW 3.0
Total power Input kW 3.8
Performance Values For Reference Condition 3
T-water outlet – 7 ℃ / T – water inlet – 12 ℃ / T-ambient – 35 ℃
Cooling capacity kW 10.0
kcal/h 8.604
Total compressor power kW 3.4
Total power Input kW 4.2
Energy efficiency ratio (EER) EER 2.4
* EER = Cooling capacity (kW) / Total Power Input (Compressor+Fan) (kW)
Number of compressors pcs. 1
Number of fans/Fan diameter pcs./mm 1xᴓ500
Fan sound level dBA 48
Required evaporator water flow m³ / h 3
Pump power ( For 3 bars ) kW 0.8
Tank volume Lt. 120

 

DIMENSIONS    
Model P-041 HA-S
L mm 1350
W mm 750
H mm 1310
Water inlet connection 1”
Water outlet connection 1”
Weight kg 210
P-071 HA-S
Model P-071 HA-S
Refrigerant  R 407 C
Performance Values For Reference Condition 1
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 25 ℃
Cooling capacity kW 26.8
kcal/h 23.059
Total compressor power kW 4.6
Total power Input kW 6.1
Performance Values For Reference Condition 2
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 32 ℃
Cooling capacity kW 24.9
kcal/h 21.424
Total compressor power kW 5.2
Total power Input kW 6.7
Performance Values For Reference Condition 3
T-water outlet – 7 ℃ / T – water inlet – 12 ℃ / T-ambient – 35 ℃
Cooling capacity kW 17.1
kcal/h 14.748
Total compressor power kW 5.7
Total power Input kW 7.2
Energy efficiency ratio (EER) EER 2.4
* EER = Cooling capacity (kW) / Total Power Input (Compressor+Fan) (kW)
Number of compressors pcs. 1
Number of fans/Fan diameter pcs./mm 2xᴓ500
Fan sound level dBA 51
Required evaporator water flow m³ / h 5
Pump power ( For 3 bars ) kW 1.5
Tank volume Lt. 230
DIMENSIONS    
Model P-071 HA-S
L mm 1620
W mm 900
H mm 1310
Water inlet connection 1”
Water outlet connection 1”
Weight kg 370
P-081 HA-S
Model P-081 HA-S
Refrigerant  R 407 C
Performance Values For Reference Condition 1  
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 25 ℃
Cooling capacity kW 34.0
kcal/h 29.254
Total compressor power  kW 5.9
Total power Input kW 7.4
Performance Values For Reference Condition 2  
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 32 ℃
Cooling capacity kW 31.5
kcal/h 27.103
Total compressor power  kW 6.6
Total power Input kW 8.1
Performance Values For Reference Condition 3  
T-water outlet – 7 ℃ / T – water inlet – 12 ℃ / T-ambient – 35 ℃
Cooling capacity kW 21.0
kcal/h 18.069
Total compressor power  kW 7.3
Total power Input kW 8.8
Energy efficiency ratio (EER) EER 2.4
* EER = Cooling capacity (kW) / Total Power Input (Compressor+Fan) (kW)
Number of compressors pcs. 1
Number of fans/Fan diameter pcs./mm 2xᴓ500
 
Fan sound level dBA 51
Required evaporator water flow m³ / h 6
Pump power ( For 3 bars ) kW 1.5
Tank volume Lt. 310
DIMENSIONS    
Model P-081 HA-S
L mm 2020
W mm 900
H mm 1310
Water inlet connection 1”
Water outlet connection 1”
Weight kg 420
P-101 HA-S
Model P-101 HA-S
Refrigerant  R 407 C
Performance Values For Reference Condition 1  
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 25 ℃
Cooling capacity kW 41.5
kcal/h 35.690
Total compressor power  kW 6.9
Total power Input kW 8.1
Performance Values For Reference Condition 2  
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 32 ℃
Cooling capacity kW 38.5
kcal/h 33.126
Total compressor power  kW 7.7
Total power Input kW 8.9
Performance Values For Reference Condition 3  
T-water outlet – 7 ℃ / T – water inlet – 12 ℃ / T-ambient – 35 ℃
Cooling capacity kW 25.9
kcal/h 22.285
Total compressor power  kW 8.5
Total power Input kW 9.7
Energy efficiency ratio (EER) EER 2.7
* EER = Cooling capacity (kW) / Total Power Input (Compressor+Fan) (kW)
Number of compressors pcs. 1
Number of fans/Fan diameter pcs./mm 2xᴓ630
 
Fan sound level dBA 53
Required evaporator water flow m³ / h 7
Pump power ( For 3 bars ) kW 2.2
Tank volume Lt. 400
DIMENSIONS    
Model P-101 HA-S
L mm 2020
W mm 1100
H mm 1440
Water inlet connection 1”
Water outlet connection 1”
Weight kg 500
P-121 HA-S
Model P-121 HA-S
Refrigerant  R 407 C
Performance Values For Reference Condition 1  
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 25 ℃
Cooling capacity kW 49.3
kcal/h 42.419
Total compressor power  kW 8.2
Total power Input kW 9.4
Performance Values For Reference Condition 2  
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 32 ℃
Cooling capacity kW 45.5
kcal/h 39.149
Total compressor power  kW 9.2
Total power Input kW 10.4
Performance Values For Reference Condition 3  
T-water outlet – 7 ℃ / T – water inlet – 12 ℃ / T-ambient – 35 ℃
Cooling capacity kW 30.4
kcal/h 26.183
Total compressor power  kW 10.2
Total power Input kW 11.4
Energy efficiency ratio (EER) EER 2.7
* EER = Cooling capacity (kW) / Total Power Input (Compressor+Fan) (kW)
Number of compressors pcs. 1
Number of fans/Fan diameter pcs./mm 2xᴓ630
 
Fan sound level dBA 53
Required evaporator water flow m³ / h 8
Pump power ( For 3 bars ) kW 2.2
Tank volume Lt. 400
DIMENSIONS    
Model P-121 HA-S
L mm 2420
W mm 1100
H mm 1440
Water inlet connection 1 ½”
Water outlet connection 1 ½”
Weight kg 550

 

P-072 HA-S
Model P-072 HA-S
Refrigerant  R 407 C
Performance Values For Reference Condition 1  
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 25 ℃
Cooling capacity kW 53.6
kcal/h 46.119
Total compressor power  kW 9.2
Total power Input kW 12.2
Performance Values For Reference Condition 2  
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 32 ℃
Cooling capacity kW 49.8
kcal/h 42.849
Total compressor power  kW 10.3
Total power Input kW 13.3
Performance Values For Reference Condition 3  
T-water outlet – 7 ℃ / T – water inlet – 12 ℃ / T-ambient – 35 ℃
Cooling capacity kW 34.3
kcal/h 29.495
Total compressor power  kW 11.3
Total power Input kW 14.3
Energy efficiency ratio (EER) EER 2.4
* EER = Cooling capacity (kW) / Total Power Input (Compressor+Fan) (kW)
Number of compressors pcs. 2
Number of fans/Fan diameter pcs./mm 3xᴓ500
 
Fan sound level dBA 53
Required evaporator water flow m³ / h 9
Pump power ( For 3 bars ) kW 2.2
Tank volume Lt. 275
DIMENSIONS    
Model P-072 HA-S
L mm 2420
W mm 1040
H mm 1440
Water inlet connection 1 ½”
Water outlet connection 1 ½”
Weight kg 675
P-082 HA-S
Model P-082 HA-S
Refrigerant  R 407 C
Performance Values For Reference Condition 1  
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 25 ℃
Cooling capacity kW 68.0
kcal/h 58.509
Total compressor power  kW 11.8
Total power Input kW 14.8
Performance Values For Reference Condition 2  
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 32 ℃
Cooling capacity kW 63.0
kcal/h 54.207
Total compressor power  kW 13.1
Total power Input kW 16.2
Performance Values For Reference Condition 3  
T-water outlet – 7 ℃ / T – water inlet – 12 ℃ / T-ambient – 35 ℃
Cooling capacity kW 42.0
kcal/h 36.138
Total compressor power  kW 14.6
Total power Input kW 17.6
Energy efficiency ratio (EER) EER 2.4
* EER = Cooling capacity (kW) / Total Power Input (Compressor+Fan) (kW)
Number of compressors pcs. 2
Number of fans/Fan diameter pcs./mm 3xᴓ500
 
Fan sound level dBA 54
Required evaporator water flow m³ / h 12
Pump power ( For 3 bars ) kW 2.2
Tank volume Lt. 275
DIMENSIONS    
Model P-082 HA-S
L mm 2420
W mm 1040
H mm 1440
Water inlet connection 2”
Water outlet connection 2”
Weight kg 725

 

P-102 HA-S
Model P-102 HA-S
Refrigerant  R 407 C
Performance Values For Reference Condition 1  
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 25 ℃
Cooling capacity kW 83.0
kcal/h 71.380
Total compressor power  kW 13.8
Total power Input kW 16.2
Performance Values For Reference Condition 2  
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 32 ℃
Cooling capacity kW 77.0
kcal/h 66.252
Total compressor power  kW 15.4
Total power Input kW 17.8
Performance Values For Reference Condition 3  
T-water outlet – 7 ℃ / T – water inlet – 12 ℃ / T-ambient – 35 ℃
Cooling capacity kW 51.8
kcal/h 44.570
Total compressor power  kW 17.0
Total power Input kW 19.4
Energy efficiency ratio (EER) EER 2.7
* EER = Cooling capacity (kW) / Total Power Input (Compressor+Fan) (kW)
Number of compressors pcs. 2
Number of fans/Fan diameter pcs./mm 3xᴓ630
 
Fan sound level dBA 43
Required evaporator water flow m³ / h 14
Pump power ( For 3 bars ) kW 3
Tank volume Lt. 350
DIMENSIONS    
Model P-102 HA-S
L mm 2850
W mm 1100
H mm 1500
Water inlet connection 2”
Water outlet connection 2”
Weight kg 825

 

P-122 HA-S
Model P-122 HA-S
Refrigerant  R 407 C
Performance Values For Reference Condition 1  
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 25 ℃
Cooling capacity kW 98.6
kcal/h 84.837
Total compressor power  kW 16.4
Total power Input kW 18.8
Performance Values For Reference Condition 2  
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 32 ℃
Cooling capacity kW 91.0
kcal/h 78.298
Total compressor power  kW 18.3
Total power Input kW 20.7
Performance Values For Reference Condition 3  
T-water outlet – 7 ℃ / T – water inlet – 12 ℃ / T-ambient – 35 ℃
Cooling capacity kW 60.9
kcal/h 52.365
Total compressor power  kW 20.4
Total power Input kW 22.8
Energy efficiency ratio (EER) EER 2.7
* EER = Cooling capacity (kW) / Total Power Input (Compressor+Fan) (kW)
Number of compressors pcs. 2
Number of fans/Fan diameter pcs./mm 3xᴓ630
   
Fan sound level dBA 43
Required evaporator water flow m³ / h 17
Pump power ( For 3 bars ) kW 3
Tank volume Lt. 350
DIMENSIONS    
Model P-122 HA-S
L mm 2850
W mm 1100
H mm 1500
Water inlet connection 2”
Water outlet connection 2”
Weight kg 875

 

Added Value

  • EASY TO USE.
  • LOW MAINTENANCE.
  • SAFE AND RELIABLE.
  • FAST INSTALLATION.

Interested in this product?

Don’t be shy…