air cooled chiller

Multi Scroll Compressors

HA-S multi-scroll SERIES

 

Conveyor belt - nds series

Planer air cooled chillers are designed to be used for Process Cooling and HVAC applications. Capacity range of standard models are between 104 – 190 kW (at the conditions of water inlet/outlet – 15/20 and air inlet 25 ) .
As standard multiple Danfoss scroll compressors are used. They are energy efficient and long-lasting.
Microprocessor controllers are used on air cooled chillers for optimum capacity control.
The used pumps are Italian made, from a world famous manufacturer – Pedrollo.

multi-scroll
multi-scroll
multi-scroll

Technical Specifications

  • 16 kW – 98 kW capacity range
  • Hermetic scroll compressor
  • Environment friendly refrigerant R 407 C
  • Direct expansion evaporator
  • 50% – 100% capacity control 
  • Electricity and power panel with CE 2006/95/EC standards 
  • High efficiency air cooled condensers, produced by PLANER
  • Axial fan, Centrifugal water pump
  • Inoxidable reserve tank 
  • Double cooling circuit for the devices with double compressors
  • Protective equipment essential for gas line
  • Compressor equal aging

Options

  • Inverter compressor and water pump 
  • Remote monitoring module
  • EC fan

 

multi-scroll
multi-scroll

ENERGY EFFICIENCY

Min. electricity consumption and max.
efficiency is reached by the innovative
solutions.

QUALITY

The devices are manufactured with first
class materials and in a manner of total
quality.

RESPECT TO ENVIROMENT

We focus on using renewable energy
resources and attain compatibility

INNOVATION

Improved by using the most effective
equipment by expert engineers

TECHNICAL SERVICE

Always with you through fast technical
service support.

TEAM

The result is attained by a team working in
complete harmony.

Model

P-074 HA-S

P-084 HA-S

P-104 HA-S

P-124 HA-S

P-154 HA-S

P-204 HA-S

P-254 HA-S

P-304 HA-S

Refrigerant  R 407 C
Performance Values For Reference Condition 1
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 25 ℃
Cooling capacity kW 107.2 136.0 166.0 197.2 216.0 295.2 356.2 442.0
kcal/h 92.192 116.960 142.760 169.592 185.760 253.872 306.332 380.120
Total compressor power  kW 18.4 23.6 27.6 32.8 39.5 55.5 67.2 83.3
Total power Input kW 20.8 26.0 30.0 35.2 42.9 63.3 78.9 95.0
Performance Values For Reference Condition 2
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 32 ℃
Cooling capacity kW 99.6 126.0 154.0 182.0 198.7 271.6 331.0 408.4
kcal/h 85.656 108.360 132.440 156.520 170.882 233.576 284.660 351.224
Total compressor power  kW 20.8 26.4 30.8 36.6 46.1 64.4 78.4 95.6
Total power Input kW 23.2 28.8 33.2 39.0 49.5 72.2 90.1 107.3
Performance Values For Reference Condition 3
T-water outlet – 7 ℃ / T – water inlet – 12 ℃ / T-ambient – 35 ℃
Cooling capacity kW 68.4 84.0 103.6 121.6 140.0 190.8 235.7 291.0
kcal/h 58.824 72.240 89.096 104.576 120.400 164.088 202.720 250.225
Total compressor power  kW 22.8 29.2 34.0 40.8 49.2 66.7 81.4 99.5
Total power Input kW 25.1 31.6 36.4 43.2 52.6 74.5 93.1 111.1
Energy efficiency ratio (EER) EER 3 2.88 3.05 2.98 2.85 2.86 2.89 2.92
* EER = Cooling capacity (kW) / Total Power Input (Compressor+Fan) (kW)
Number of compressors pcs. 4 4 4 4 4 4 4 4
Number of fans/Fan diameter pcs./mm 6xᴓ500 6xᴓ500 6xᴓ500 4xᴓ710 4xᴓ710 4xᴓ800 6xᴓ800 6xᴓ800
Fan sound level dBA 48 51 51 53 53 53 58 58
Required evaporator water flow m³ / h 19 23 28 34 37 50 61 76
Pump power ( For 3 bars ) kW 3 3 4 4 7.5 7.5 11 11
Tank volume Lt. 300 350 350 400 600 600 800 800

DIMENSIONS

Model P-074 HA-S P-084 HA-S P-104 HA-S P-124 HA-S P-154 HA-S P-204 HA-S P-254 HA-S P-304 HA-S
L mm 2950 2950 2950 3020 3020 3330 3750 3750
W mm 1590 1590 1590 2050 2050 2250 2250 2250
H mm 2090 2090 2090 2280 2280 2670 2670 2670
Water inlet connection 2” 2” 2” 2 ½” 3” 3” 3” DN 125
Water outlet connection 2” 2” 2” 2 ½” 3” 3” 3” DN 125
Weight kg 1280 1400 1520 1750 2100 2200 2600 3100

Technical Data

P-074 HA-S
Model P-074 HA-S
Refrigerant  R 407 C
Performance Values For Reference Condition 1  
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 25 ℃
Cooling capacity kW 107.2
kcal/h 92.192
Total compressor power  kW 18.4
Total power Input kW 20.8
Performance Values For Reference Condition 2  
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 32 ℃
Cooling capacity kW 99.6
kcal/h 85.656
Total compressor power  kW 20.8
Total power Input kW 23.2
Performance Values For Reference Condition 3  
T-water outlet – 7 ℃ / T – water inlet – 12 ℃ / T-ambient – 35 ℃
Cooling capacity kW 68.4
kcal/h 58.824
Total compressor power  kW 22.8
Total power Input kW 25.1
Energy efficiency ratio (EER) EER 3
* EER = Cooling capacity (kW) / Total Power Input (Compressor+Fan) (kW)
 
Number of compressors pcs. 4
Number of fans/Fan diameter pcs./mm 6xᴓ500
 
Fan sound level dBA 48
Required evaporator water flow m³ / h 19
Pump power ( For 3 bars ) kW 3
Tank volume Lt. 300
DIMENSIONS    
Model P-074 HA-S
L mm 2950
W mm 1590
H mm 2090
Water inlet connection 2”
Water outlet connection 2”
Weight kg 1280
P-084 HA-S
Model P-084 HA-S
Refrigerant  R 407 C
Performance Values For Reference Condition 1  
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 25 ℃
Cooling capacity kW 136.0
kcal/h 116.960
Total compressor power  kW 23.6
Total power Input kW 26.0
Performance Values For Reference Condition 2  
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 32 ℃
Cooling capacity kW 126.0
kcal/h 108.360
Total compressor power  kW 26.4
Total power Input kW 28.8
Performance Values For Reference Condition 3  
T-water outlet – 7 ℃ / T – water inlet – 12 ℃ / T-ambient – 35 ℃
Cooling capacity kW 84.0
kcal/h 72.240
Total compressor power  kW 29.2
Total power Input kW 31.6
Energy efficiency ratio (EER) EER 2.88
* EER = Cooling capacity (kW) / Total Power Input (Compressor+Fan) (kW)
 
Number of compressors pcs. 4
Number of fans/Fan diameter pcs./mm 6xᴓ500
 
Fan sound level dBA 51
Required evaporator water flow m³ / h 23
Pump power ( For 3 bars ) kW 3
Tank volume Lt. 350
DIMENSIONS    
Model P-084 HA-S
L mm 2950
W mm 1590
H mm 2090
Water inlet connection 2”
Water outlet connection 2”
Weight kg 1400
P-104 HA-S
Model P-104 HA-S
Refrigerant  R 407 C
Performance Values For Reference Condition 1  
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 25 ℃
Cooling capacity kW 166.0
kcal/h 142.760
Total compressor power  kW 27.6
Total power Input kW 30.0
Performance Values For Reference Condition 2  
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 32 ℃
Cooling capacity kW 154.0
kcal/h 132.440
Total compressor power  kW 30.8
Total power Input kW 33.2
Performance Values For Reference Condition 3  
T-water outlet – 7 ℃ / T – water inlet – 12 ℃ / T-ambient – 35 ℃
Cooling capacity kW 103.6
kcal/h 89.096
Total compressor power  kW 34.0
Total power Input kW 36.4
Energy efficiency ratio (EER) EER 3.05
* EER = Cooling capacity (kW) / Total Power Input (Compressor+Fan) (kW)
 
Number of compressors pcs. 4
Number of fans/Fan diameter pcs./mm 6xᴓ500
 
Fan sound level dBA 51
Required evaporator water flow m³ / h 28
Pump power ( For 3 bars ) kW 4
Tank volume Lt. 350
DIMENSIONS    
Model P-104 HA-S
L mm 2950
W mm 1590
H mm 2090
Water inlet connection 2”
Water outlet connection 2”
Weight kg 1520

 

P-124 HA-S
Model P-124 HA-S
Refrigerant  R 407 C
Performance Values For Reference Condition 1  
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 25 ℃
Cooling capacity kW 197.2
kcal/h 169.592
Total compressor power  kW 32.8
Total power Input kW 35.2
Performance Values For Reference Condition 2  
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 32 ℃
Cooling capacity kW 182.0
kcal/h 156.520
Total compressor power  kW 36.6
Total power Input kW 39.0
Performance Values For Reference Condition 3  
T-water outlet – 7 ℃ / T – water inlet – 12 ℃ / T-ambient – 35 ℃
Cooling capacity kW 121.6
kcal/h 104.576
Total compressor power  kW 40.8
Total power Input kW 43.2
Energy efficiency ratio (EER) EER 2.98
* EER = Cooling capacity (kW) / Total Power Input (Compressor+Fan) (kW)
 
Number of compressors pcs. 4
Number of fans/Fan diameter pcs./mm 4xᴓ710
 
Fan sound level dBA 53
Required evaporator water flow m³ / h 34
Pump power ( For 3 bars ) kW 4
Tank volume Lt. 400
DIMENSIONS    
Model P-124 HA-S
L mm 3020
W mm 2050
H mm 2280
Water inlet connection 2 ½”
Water outlet connection 2 ½”
Weight kg 1750
P-154 HA-S
Model P-154 HA-S
Refrigerant  R 407 C
Performance Values For Reference Condition 1  
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 25 ℃
Cooling capacity kW 216.0
kcal/h 185.760
Total compressor power  kW 39.5
Total power Input kW 42.9
Performance Values For Reference Condition 2  
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 32 ℃
Cooling capacity kW 198.7
kcal/h 170.882
Total compressor power  kW 46.1
Total power Input kW 49.5
Performance Values For Reference Condition 3  
T-water outlet – 7 ℃ / T – water inlet – 12 ℃ / T-ambient – 35 ℃
Cooling capacity kW 140.0
kcal/h 120.400
Total compressor power  kW 49.2
Total power Input kW 52.6
Energy efficiency ratio (EER) EER 2.85
* EER = Cooling capacity (kW) / Total Power Input (Compressor+Fan) (kW)
 
Number of compressors pcs. 4
Number of fans/Fan diameter pcs./mm 4xᴓ710
 
Fan sound level dBA 53
Required evaporator water flow m³ / h 37
Pump power ( For 3 bars ) kW 7.5
Tank volume Lt. 600
DIMENSIONS    
Model P-154 HA-S
L mm 3020
W mm 2050
H mm 2280
Water inlet connection 3”
Water outlet connection 3”
Weight kg 2100
P-204 HA-S
Model P-204 HA-S
Refrigerant  R 407 C
Performance Values For Reference Condition 1  
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 25 ℃
Cooling capacity kW 295.2
kcal/h 253.872
Total compressor power  kW 55.5
Total power Input kW 63.3
Performance Values For Reference Condition 2  
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 32 ℃
Cooling capacity kW 271.6
kcal/h 233.576
Total compressor power  kW 64.4
Total power Input kW 72.2
Performance Values For Reference Condition 3  
T-water outlet – 7 ℃ / T – water inlet – 12 ℃ / T-ambient – 35 ℃
Cooling capacity kW 190.8
kcal/h 164.088
Total compressor power  kW 66.7
Total power Input kW 74.5
Energy efficiency ratio (EER) EER 2.86
* EER = Cooling capacity (kW) / Total Power Input (Compressor+Fan) (kW)
 
Number of compressors pcs. 4
Number of fans/Fan diameter pcs./mm 4xᴓ800
 
Fan sound level dBA 53
Required evaporator water flow m³ / h 50
Pump power ( For 3 bars ) kW 7.5
Tank volume Lt. 600
DIMENSIONS    
Model P-204 HA-S
L mm 3330
W mm 2250
H mm 2670
Water inlet connection 3”
Water outlet connection 3”
Weight kg 2200

 

P-254 HA-S
Model P-254 HA-S
Refrigerant  R 407 C
Performance Values For Reference Condition 1  
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 25 ℃
Cooling capacity kW 356.2
kcal/h 306.332
Total compressor power  kW 67.2
Total power Input kW 78.9
Performance Values For Reference Condition 2  
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 32 ℃
Cooling capacity kW 331.0
kcal/h 284.660
Total compressor power  kW 78.4
Total power Input kW 90.1
Performance Values For Reference Condition 3  
T-water outlet – 7 ℃ / T – water inlet – 12 ℃ / T-ambient – 35 ℃
Cooling capacity kW 235.7
kcal/h 202.720
Total compressor power  kW 81.4
Total power Input kW 93.1
Energy efficiency ratio (EER) EER 2.89
* EER = Cooling capacity (kW) / Total Power Input (Compressor+Fan) (kW)
 
Number of compressors pcs. 4
Number of fans/Fan diameter pcs./mm 6xᴓ800
 
Fan sound level dBA 58
Required evaporator water flow m³ / h 61
Pump power ( For 3 bars ) kW 11
Tank volume Lt. 800
DIMENSIONS    
Model P-254 HA-S
L mm 3750
W mm 2250
H mm 2670
Water inlet connection 3”
Water outlet connection 3”
Weight kg 2600
P-304 HA-S
Model P-304 HA-S
Refrigerant  R 407 C
Performance Values For Reference Condition 1  
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 25 ℃
Cooling capacity kW 442.0
kcal/h 380.120
Total compressor power  kW 83.3
Total power Input kW 95.0
Performance Values For Reference Condition 2  
T-water outlet – 15 ℃ / T – water inlet – 20 ℃ / T-ambient – 32 ℃
Cooling capacity kW 408.4
kcal/h 351.224
Total compressor power  kW 95.6
Total power Input kW 107.3
Performance Values For Reference Condition 3  
T-water outlet – 7 ℃ / T – water inlet – 12 ℃ / T-ambient – 35 ℃
Cooling capacity kW 291.0
kcal/h 250.225
Total compressor power  kW 99.5
Total power Input kW 111.1
Energy efficiency ratio (EER) EER 2.92
* EER = Cooling capacity (kW) / Total Power Input (Compressor+Fan) (kW)
   
Number of compressors pcs. 4
Number of fans/Fan diameter pcs./mm 6xᴓ800
   
Fan sound level dBA 58
Required evaporator water flow m³ / h 76
Pump power ( For 3 bars ) kW 11
Tank volume Lt. 800
DIMENSIONS    
Model P-304 HA-S
L mm 3750
W mm 2250
H mm 2670
Water inlet connection DN 125
Water outlet connection DN 125
Weight kg 3100

Added Value

  • EASY TO USE.
  • LOW MAINTENANCE.
  • SAFE AND RELIABLE.
  • FAST INSTALLATION.

Interested in this product?